<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-07 21-38-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.10 MHz 5/5, 56 dBuV ICI
Pilot RDS Phase Difference
6.8 kHz 4.0 kHz 4 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
30 kHz 72 kHz 10040 0,5378
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
5,5 dBr 6,32 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" ICI " F20A 0 (No PTY) 1 0 1 1 21:38, 7.03.2025
RT
"2025, AU PAYS DES ENFOIRES, LE CONCERT - ICI PARIS IDF "
AF EON
92.7, 97.3, 101.4, 103.3, 107.1 MHz F204, F202, F206, F201
FM Scope Station: 107.10 MHz, signal: 5/5 (56 dBuV) Max at: 72 kHz MIN: 30 kHz % above 75 kHz: 0,5378 Acquired: 2025/03/07 21:37:07 Total samples: 10040 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 7,0 dBr MIN: 5,5 dBr AVE: 6,32 dBr % above 10,0 dBr: 0,0 Last value: 6,4 dBr (2025/03/07 21:37:06) Station: 107.10 MHz, signal: 5/5 (56 dBuV) 21:30 21:31 21:32 21:33 21:34 21:35 21:36 21:37 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality